Carrier® WeatherMaker™ - 6 Ton Packaged Rooftop Heat Pump Unit, Med. Static (208/230-3-60)

Item: 50TCQA07A2A5-0A0A0
MFR: 50TCQA07A2A5-0A0A0

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
Equipment part list is available.
What’s the price?
Sign in for pricing.
Decrease quantity
Increase quantity

Description

50TCQA07A2A5-0A0A0
50TC = WeatherMaker® Packaged Rooftop
Q = Heat Pump
A = One Stage Cooling Models
07 = 6 ton
A = None
2 = Medium Static Option - Belt Drive
A = Al/Cu - Al/Cu
5 = 208/230-3-60
= Factory Design Revision
0 = Electro-mechanical Controls can be used with W7212 EconoMi$er IV (Non-Fault Detection and Diagnostic
A = None
0 = None
A = None
0 = Standard

Your Carrier Packaged Heat Pump rooftop unit (RTU) was designed by customers for customers. With no-strip screw collars, handled access panels, and more we’ve made your unit easy to install, easy to maintain and easy to use.
Easy to install:
All WeatherMaker™ units are field-convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Carrier 3 - 12.5 ton 50TCQ rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls.
Easy to maintain:
Easy access handles by Carrier provide quick and easy access to all normally serviced components. Our “no-strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take refrigeration system pressure readings without affecting the condenser airflow.
Easy to use:
The newly designed, central terminal board by Carrier puts all your connections and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Carrier rooftops have high and low pressure switches, a filter drier, and 2-in. (51mm) filters standard.

FEATURES AND BENEFITS
  • SEER up to 13.4, EER up to 11.2.
  • IEER up to 12.2 with single speed indoor fan motor and up to 12.5 with 2-speed/VFD indoor fan motor.
  • Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
  • 3 - 12.5 ton units fit on existing Carrier rooftop curbs making the utility connections the same. This saves time and money on replacement jobs.
  • Standardized components and layout. Standardized components and controls make service and stocking parts easier.
  • Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble-shooting easier.
  • Crankcase heater on all models (except 04 size) provides added protection in all applications.
  • Precision-sized suction line accumulator provides high reliability by preventing liquid from entering the compressor during low ambient conditions and reverse cycle switch over.
  • Field convertible from vertical to horizontal airflow configuration on all models. No special kit required on 04-12 models. Supply duct kit required for 14 model only.
  • 4-way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating to cooling.
  • Easy-adjust, belt drive motor available on all sizes. There’s no need for field-supplied drives or motors.
  • 3-5 ton models come standard with Direct Drive X13, 5 speed/torque motor to provide exact performance in many applications. Belt drive motor optional.
  • Provisions for bottom or side condensate drain.
  • Capable of thru-the-base or thru-the-curb electrical routing.
  • Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is adjustable.
  • Single-point electrical connection.
  • Sloped, composite drain pan sheds water; and won’t rust.
  • Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier.
  • Clean, large, easy to use control box.
  • Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design.
  • Color-coded wiring.
  • Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
  • Single, central terminal board for test and wiring connections.
  • Fast-access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
  • “No-strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit.
  • Exclusive, newly-designed indoor refrigerant header for easier maintenance and replacement.
  • Mechanical cooling (115°F to 25°F or 46°C to -4°C) on Electro-Mechanical (E/M) and Direct Digital Controller (DDC) (PremierLinkt or RTU Open controller).
  • 2-in. (51mm) disposable filters on all units.
  • High capacity refrigerant filter drier on each circuit.
  • High pressure switch, loss of charge switch and freeze protection adds greater unit reliability.
  • Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on 2-stage cooling models 08-14 with electromechanical controls or RTU Open.

Documentation

Specifications

Weight607 Pound (lb.)
Width74.375 Inches (in)
Height41.375 Inches (in)
Country of OriginMEX
UPC or Barcode1P50TCQA07A2A5-0A0A0
Hazardous MaterialNo
EPA Cert RequiredNo
Length46.75 Inches (in)
Air FlowConvertible
Blower Motor RPM1066-1380
BrandCarrier
CFM3000
CFM Cooling1800-3000
CFM Heating1800-3000
ColorGray
Condenser Motor HP1/4 HP
Cooling Capacity70000
Cycle/Hertz60
Drain Connection Size3/4"
Drive TypeBelt
EER11
Energy Star RatedNo
Equipment TypeStraight Cool
Filter Size(4)16" x 16" x 2"
Heating Capacity66000,31800
HSPF2.25,3.5
IEER11.4
ISO CodeMX
PhaseThree
RefrigerantR-410a
Sound Level (dBA)78
StageSingle
TierWeatherMaker
Tonnage6
UL ListedYes
UL RecognizedYes
Voltage208-230 VAC
Watts325