Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
#

Carrier® Comfort™ Ductless 22,000 Btuh Cooling Condenser Single Zone 208/230-1 (Matches 40MFC High Wall)

Item: 38MFC022---3
MFR: 38MFC022---3

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
Equipment part list is available.
What’s the price?
Sign in for pricing.
Decrease quantity
Increase quantity

Description

38MFC022---3
38 = Air-Cooled Condenser
MFC = Cooling Only Unit Type
022 = 1.83 Tons Nominal Capacity
3 = 208/230-1-60 Voltage

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.

The 38/40MFC(Q) series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits creative solutions to design problems such as:
  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system.
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork.
  • Historical renovations or any application where preserving the look of the original structure is essential.

The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.

These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. When sound ordinances and proximity to neighbors demand quiet operation, the 38MFC,MFQ unit is the right choice: The advanced, horizontal airflow design distributes air more evenly over the coil.

SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MFC,MFQ units can be installed close to an outside wall, coils are protected from vandals and severe weather.

FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38/40MFC,MFQ ductless split systems the equipment of choice, especially in retrofit situations.

SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these high wall systems have extensive self-diagnostics to assist in troubleshooting.

BUILT-IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation. The high wall indoor units include protection against freeze-up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor will start the over-current protection and the high temperature protection.

INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.

ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply- air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts.

EASY-TO-USE CONTROLS
The high--wall units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit.

ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished. Adding a condensate pump accessory to the high wall fan coil provides installation flexibility.

OPTIONAL WIRED CONTROLLER AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight98.1 Pound (lb.)
Width38 Inches (in)
Height29.7 Inches (in)
Country of OriginVar
UPC or Barcode1P38MFC022---3
Hazardous MaterialNo
EPA Cert RequiredNo
Length15.6 Inches (in)
BrandCarrier
CFM1390
Condenser Motor HP18/25 HP
Cooling Capacity22000
Cycle/Hertz60
EER10
Equipment TypeStraight Cool
ISO CodeVaries
Liquid Line Fitting3/8"
Maximum Fuse Size25
Maximum Piping Length98'
Minimum Circuit Amps16
Number of HVAC Zones1
PhaseSingle
Product Family38MFC
RefrigerantR-410a
Rows2
SEER15
Sound Level (dBA)61
StageVariable
Suction Line Fitting5/8"
TierComfort
Tonnage1.83
Voltage208-230 VAC

Equipment Part List