Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
#

Carrier® Infinity™ Ductless 24,000 Btuh Heat Pump Ducted (Matches 38GJQ)

Item: 40GJQB24D--3
MFR: 40GJQB24D--3

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
Equipment part list is available.
What’s the price?
Sign in for pricing.
Decrease quantity
Increase quantity

Description

40GJQB24D--3
40 = FAN COIL UNIT
GJ = CASSETTE, DUCTED, FLOOR CONSOLE, HIGHWALL
Q = HEAT PUMP SYSTEM TYPE
B = ALL
24 = 2 TON NOMINAL CAPACITY
D = DUCTED INDOOR FAN COIL TYPE
-- = NOT USED
3 = 208/230-1-60 VOLTAGE

AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS.
The 38GJ / 40GJ / 40GR ductless inverter driven multi- split system provides individual comfort control for up to 9 separate zones. Two, three, four, five, six, seven, eight or nine space-saving cassette, floor console, high wall, or ducted fan coils can be matched with one outdoor heat pump. The indoor fan coils are connected to the outdoor unit by refrigerant tubing and wires.
The different styles of indoor units can be mounted in several locations to accommodate the application. This selection of fan coils permits inexpensive and creative solutions to design problems such as:
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork.
  • Historical renovations or any application where preserving the look of the original structure is essential.
  • Commercial add-on jobs where the existing air conditioning system cannot be stretched.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors.
Advanced system components incorporate innovative technology to provide reliable cooling and heating performance at low sound levels.

INVERTER TECHNOLOGY
The inverter driven compressor is designed to run at various input power frequencies (Hz) which controls the motor speed of the compressor.
Even Temperature - The control package, including the inverter, monitors outdoor and indoor temperatures as they relate to the selected indoor set point and adjusts the speed of the compressor to match the load and keep the system operating continuously rather than cycling and creating temperature swings. This translates to higher comfort levels for the occupants.
Rapid Pull Down/Warm-Up - Comfort is increased by the ability to the inverter system to ramp up the compressor speed enabling the system to reach the user selected room temperature set point quicker.
Humidity Control - Running the system for longer periods and continuously varying the compressor speed will enhance the humidity control.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on the usage pattern. The air sweep feature provided permits optimal room mixing to eliminate hot and cold spots for the occupant comfort.
LOW SOUND LEVELS
When noise is a concern, ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38GJ unit is the right choice. With the inverter technology, these units run at lower speeds most of the time resulting in reduced sound levels.
INVERTER TECHNOLOGY – ENHANCED ECONOMICAL OPERATION
Ductless systems are inherently economical to operate. Individual rooms are heated or cooled only when required, and since the air is delivered directly to the space, there is no need to use additional energy to move the air in the ductwork. This economical operation is enhanced further when the inverter system output matches the load resulting in a more efficient system.
EASY-TO-USE CONTROLS
The multi- zone systems have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote controls provide the interface between the user and the unit.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork or wall openings. In addition, since the 38GJ can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is included with the indoor units and only wires and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in homes or workplace. This makes the 38GJ / 40GJ / 40GR systems the equipment of choice for retrofit applications.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel of the outdoor unit provides immediate access to the control compartment, providing the service technician access to the diagnostic LEDs to facilitate the troubleshooting process. In addition, the draw-thru design of the outdoor unit means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On the indoor units, service and maintenance expense is reduced due to the permanent easy to clean filters. Also, error codes are displayed on the front panel to alert the user to certain system malfunctions
BUILT- IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
Both the indoor and outdoor units are well protected. Whenever the microprocessor detects abnormal conditions, the unit will stop and an error code is displayed.
Inverter systems provide additional reliability due to soft start. This refers to the ability of the inverter to start the compressor motor using reduced voltage and reduced current. This feature is beneficial from an electrical standpoint (eliminates current spikes) as well as an overall reliability standpoint due to reduced stress on all associated system components.
CONDENSATE PUMP
A condensate pump accessory is available (High Wall and Floor Console) to provide installation flexibility for those applications where gravity cannot be used to dispose of the condensate.
Factory installed condensate pump on the Ducted and Cassette fan coils provides installation flexibility.
AGENCY LISTINGS
All systems are listed with AHRI (Air conditioning, Heating, and Refrigeration Institute) and are ETL certified per UL 1995 standard.

Specifications

Weight68.3 Pound (lb.)
Width24.2 Inches (in)
Height7.9 Inches (in)
Country of OriginCHN
UPC or BarcodeN/A
Hazardous MaterialNo
EPA Cert RequiredNo
Length27.6 Inches (in)
BrandCarrier
CFM588
ColorBrown
Cooling Capacity24000
Cycle/Hertz60
Energy Star RatedNo
Equipment TypeHeat Pump
Heating Capacity24000
ISO CodeCN
Liquid Line Fitting3/8"
Mounting TypeDucted
PhaseSingle
Product Family40GJD
RefrigerantR-410a
Sound Level (dBA)42
Suction Line Fitting5/8"
TierInfinity
Tonnage2
Voltage208-230 VAC