Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
#

Bryant® Preferred™ - 2.5 Ton, 14 SEER, Residential Packaged Heat Pump Unit (Tin-Plated Indoor Coil)

Item: 607CNXA30000--TP
MFR: 607CNXA30000--TP

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
Equipment part list is available.
What’s the price?
Sign in for pricing.
Decrease quantity
Increase quantity

Description

Variations
FE - Economizer (3 Phase Only)
TF - Filter Rack
TP - Base unit with tin plated indoor coil hairpins (Single Phase)
Only used if ordering an option

Single-Packaged Products with Energy-Saving Features and Puron® refrigerant.
  • Up to 14.5 SEER
  • 8.0 HSPF
  • 12 EER at 95°F (35°C) OD
  • Factory-Installed TXV
  • ECM Motor-Standard
FEATURES / BENEFITS

One-piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance.
Efficient operation High-efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 14.5.
Puron Environmentally Sound Refrigerant is Bryant’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems, proving highly reliable, environmentally sound performance.
Easy Installation
Factory-assembled package is a compact, fully self-contained, heat pump unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications.
Durable, dependable components Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection.
ECM Motor is standard on all 607C----A models. Direct-drive, PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field installed accessory.
Innovative Unit Base Design
On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging.
Thermostat Controls designed to work as a system with Bryant’s small packaged product.
Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency.
Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier.
High and Low Pressure Switches provide added reliability for the compressor.
Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit.
Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA.
Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4-in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow with the two standard duct covers. Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes seals on the bottom openings to ensure a positive seal in the vertical airflow mode.
Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided.
Short-Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason.

Documentation

Specifications

Weight340 Pound (lb.)
Width32.625 Inches (in)
Height44.125 Inches (in)
Country of OriginVar
UPC or BarcodeN/A
Hazardous MaterialNo
EPA Cert RequiredNo
Length48.1875 Inches (in)
Air FlowConvertible
Blower Motor HP1/2 HP
Blower Motor SpeedsVariable
Blower Motor TypeECM
Blower Wheel10" x 10"
BrandBryant
CertificationsAHRI; ASHRAE 90.1
CFM Cooling1000
Compressor(1) Scroll
Condenser Motor HP1/10 HP
Condenser Motor RPM810
Condenser Motor Speeds1
Condenser Motor TypePSC
Cooling Capacity28600
COP2.35
Cycle/Hertz60
Drive TypeDirect
EER12
Electric Heat Range [kW]0-15
Energy Star RatedYes
Equipment TypeHeat Pump
ETL CertifiedNo
ETL ListedNo
Heating Capacity15600,28400
HSPF8
ISO CodeVaries
LEED CertifiedNo
Locked Rotor Amps73
Metering DeviceIndoor TXV, Outdoor Dual Accuaraters
Number of Fan Blades1
PhaseSingle
Rated Load Amps14.1
RefrigerantR-410a
SEER14
Sound Level (dBA)75
StageSingle
TierPreferred
Tonnage2.5
UL ListedYes
UL RecognizedYes
Voltage208-230 VAC

Equipment Part List